All checks were successful
Check / eval (push) Successful in 2m58s
charge_control_end_threshold was written (80) but charge_types stayed [Adaptive], which ignores the cap while still reporting it — battery kept charging past 80% on Latitude. Oneshot now selects Custom when a limit is set, Adaptive/Standard when off; sets start hysteresis; doctor warns if type ≠ Custom while limited. V0: flake check --no-build green. V3: re-apply limit, confirm charge_types shows [Custom] and status stops Charging above cap.
5.7 KiB